Brand Name : TC
Model Number : CAG61220
Place of Origin : China
Material : Cold rolled steel, Tempered Glass
Surface Treatment : Electrostatic Powder Sprayed in Surface
Electrostatic Protection : In accordance with GB50611
Power Supply and Distribution : In accordance with GB50052, GB50054
Lightning Protection : In accordance with GB50343
Air Conditioning : In accordance with GB50019, GB50243
Fire Extinction : In accordance with GB50263
Standard : GB/T 18233 (ISO/IEC 11801); GB 50311; GB50174; TIA/EIA568-C.2
Data Center Containment, Data Center Cooling System Application
Data center cabinets are facing a lot of challenges: higher heat density, greater electric energy consumption, lack of space, and cabinet layout not keeping up with the needs of business growth.
There has always been increasingly requirements for cooling, though air conditioners are frequently replaced and added.
However, there still exists the partial heat island problem, that is, direct mix of cold and hot air resulting in huge waste of cooling capacity.
The equipment on top of the cabinet cannot acquire enough cooling capacity as needed, so the overall PUE value still remains high.
The cold/hot aisle containment system separates the cold inlet air and the hot exhaust air. The cold air is pushed under the raised floor and through the closed cold aisle. As the cold air concentrates in front of the cabinet and cools the equipment, it is heated and eventually dissipated into the hot aisle. The hot exhaust air is then routed back to the outlet of air conditioner.
Product Features
Thanks to the hot aisle and cold aisle, the cabinets are no longer placed in the same direction.
The fronts of the racks face each other, which fits for the front-to-back heat dissipation of most IT equipment. In doing this, an unnecessary mix of cold and hot air is thus avoided for improved cooling efficiency.
Application Standards
GB/T 18233 (ISO/IEC 11801); GB 50311; GB50174; TIA/EIA568-C.2
Aisle Components
Functional Skylight
Fire Fighting Linkage Retractable Skylight
Fully Transparent Fixed Skylight
Electric Sliding Door
Double Flush Door
Double Manual Sliding Door
Technical Details
Specifications | |
Range of Altitude | 0-2000 m |
Operating Temperature Range | -15℃to 45℃ |
Operating Humidity Range | 0 to 85% |
Electrostatic Protection | In accordance with GB50611 |
Power Supply and Distribution | In accordance with GB50052, GB50054 |
Lightning Protection | In accordance with GB50343 |
Air Conditioning | In accordance with GB50019, GB50243 |
Fire Extinction | In accordance with GB50263 |
19-inch Cabinet | In accordance with GB3047.2, IEC297-2, DIN41491 PART1, DIN41494 PART7, ANSI/EIARS-310-D; compatible with ETSI |
![]() |