Sign In | Join Free | My gimpguru.org |
|
Brand Name : TC
Model Number : FTP-51-6-4P-T1
Certification : UL, RoSH, REACH, CE
Place of Origin : China
MOQ : 50 Boxes
Price : Negotiable
Payment Terms : Western Union, T/T, L/C, MoneyGram
Packaging Details : Seaworthy Packing
Type : Cat 6 F/UTP
Outer Jacket : TPU, black
Insulation : HDPE
Cross Spline : PE
Conductor Material : 99.99% BC
Conductor OD : 23 AWG
Drain Wire : Yes
Rip Cord : No
Cat 6 Cable, Cat 6 Network Cable, Cat 6 Ethernet Cable, TPU sheath, outdoor application
It can be applied in harsh field environments or indoor industrial environments where cable properties, such as abrasion, corrosion, oil/weather/ozone resistance, pulling force, high and low temperature, must be good.
Product Features
TC's Cat 6, 23 AWG, 4-pair shielded tactical cable adopts cross-type spline and overall aluminum foil shield, optimized to greatly enhance technical indicators, including Attenuation, NEXT, and ANEXT. Its unique TPU jacket ensures highly efficient data transmission even exposed to the field, industrial environment and other harsh environments.
Its performance exceeds all the parameters specified in IEC 61156-5 standards.
And the cable is especially useful in some harsh electromagnetic environments where high-speed and stable cable transmission is required.
At the same time, it acts on the requirements for structured cabling in new buildings.
Application Standards
ISO/IEC 11801
Technical Details
Transmission Performance | Cat.6 | TC | |||||
Frequency (MHz) | 4 | 31.25 | 62.5 | 100 | 200 | 250 | 350 |
IL Attenuation (dB/100M) | 3.4 | 9.5 | 13.5 | 17.2 | 24.8 | 28 | 31 |
Near End Crosstalk Attenuation (NEXT, dB) | 94 | 77.4 | 69.5 | 72.9 | 65.3 | 61.9 | 62.4 |
NEXT Power and PS NEXT (dB) | 73.9 | 69.9 | 61.7 | 64.3 | 59.6 | 61 | 58.6 |
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) | 108.9 | 99.2 | 90.7 | 107.2 | 82.8 | 77.2 | 74.6 |
ACR-F Power and PS ACR-F (dB) | 94.4 | 91.2 | 87.9 | 90.5 | 77 | 73.8 | 70.5 |
Return Loss (RL, dB) | 37.3 | 37.5 | 37.3 | 31.6 | 23.4 | 24.2 | 22.8 |
Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.
Electrical Properties | |
DC resistance (20℃ ) | 93.8Ω/km |
Earth Capacity | ≦ 5.6 nF/100m (@1kHz) |
100MHz Characteristic Impedance | 100Ω±15Ω |
Transverse Conversion Loss (TCL) | ≥ 55dB-20×lgf (100-2000MHz) |
Delay Skew | 25ns/100m |
Mechanical Properties | |
Minimum Bend Radius (dynamic) | 32mm |
Minimum Bend Radius (static) | 60mm |
Maximum Installation Tension | 150N |
Anti-Extrusion Capacity | 1000N/10cm |
Flammability (TPU) | |
TPU Flame Resistance | GB/T 18380.12 (IEC 60332-1-2) |
![]() |